Triazine structures

SupelMIP™ Triazine10

- A class selective SPE sorbent for extraction of Triazines and Triazine metabolites from water, soil and food products.

Background

Triazines represent a class of herbicides used in agricultural settings to control weeds, plants and broadleaf. Atrazine, simazine and propazine are three of the more common examples of triazines, having the general structure shown below. Despite their widespread use, they are known to be harmful to animals and humans. Because of such health concerns herbicides (and pesticides) are strictly regulated in the European Union. The use of triazines is forbidden in most European countries, including Sweden. The European Legislation allows a maximum of 0.1 µg/l in drinking water. The US EPA has also set limits on the amounts of atrazine allowed in public drinking water supplies, food and animal feed. The ability to detect triazines is obviously a global issue of importance and a satisfactory analytical method for these compounds is in great demand.

Compound X R1 R2 Triazine structure
Atrazine Cl CH(Me)2 C2H5
Simazine Cl C2H5 C2H5
Propazine Cl CH(Me)2 CH(Me)2
Cyanazine Cl C2H5 CMe(CN)
Sebutylazine Cl C2H5 CHMe(Et)
Deisopropylatrazine Cl H C2H5
Deethylatrazine Cl CH(Me)2 H
Deethylterbutylazine Cl C(Me)3 H
Prometon MeO CH(Me)2 CH(Me)2
Hydroxyterbutylazine OH C(Me)3 C2H5

Features and applications

SupelMIP™ Triazine10 allows fast and robust extraction of Triazines and Triazine metabolite at low detection levels (ppb) from industrial wastewater, environmental samples of drinking and river water, as well as from food samples. SupelMIP™ Triazine10 shows excellent selectivity towards the following triazines and triazine metabolites: atrazine, simazine, propazine, cyanazine, sebutylazine, deisopropylatrazine, deethylatrazine, deethylterbutylazine, prometon and hydroxyterbutylazine.

The analysis and extraction of triazines and triazine metabolites from water, with high recoveries even when present at very low levels (ppb), are characteristics of the new SupelMIP™ Triazine10 The recoveries are reproducible and in the range 80-95%. Due to the excellent selectivity of the SupelMIP™ Triazine10 less ‘chemical noise’ is obtained compared to conventional extraction methods, resulting in lower detection limits in GCMS or LCMS analysis. This also facilitates reduced sample volumes, quicker analysis times and a more cost effective extraction method. The SupelMIP™ Triazine10 is available in a wide selection of column formats including columns for automated solid-phase extraction systems

More information about SupelMIP™ Triazine10 product can be found in the Product Bulletin.
Recovery, precision and accuracy are given together with chromatograms and SPE procedure in the Data Sheet.

Order code Sorbent mass Column volume Columns/box Order
53208-U 25 mg 10 ml 50 link www.sigmaaldrich.com
SupelMIP cartridges available from Sigma-Aldrich

Newsletter

Get MIP Technologies newsletter

If you would like to subscribe to our newsletter, you can fill in the form below.